Gas adjustment (Conversion to LPG)
All work must be carried out by a CORGI registered
engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o Remove the pan-stands, burners and
flame spreaders (A).
o Unscrew the injector (B) and replace it
with the stipulated injector for the new gas
supply (see table below).
GENERAL INJECTORS TABLE
Power Watt Kind of gas Nozzle
mm/100
Burners
Position-Type
max.
min.
129 -Rapid 3000
750
97 -Semi rapid 1750
440
NATURAL
72 -Auxiliary 1750
300
87 -Rapid 3000
750
65 -Semi rapid 1750
440
L.P.G
52 -Auxiliary 1000
300
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o IMPORTANT: The minimum flow adjustment process must
be completed before the appliance is next used.